Leave Your Message

AYAA · UAV BATTERY MANAGEMENT

EF-003 8S–14S 150A UAV BMS

For UAV battery pack engineers, EF-003 monitors individual cell voltages, pack current and four NTC temperature channels. Configurable protection thresholds, charge and idle-state balancing, and a DroneCAN interface support system integration and pack telemetry.

8S–14S Supported Series-Cell Range
80 A / 120 A Recommended Continuous Charge / Discharge
±5 mV Cell-Voltage Accuracy at 25°C
DroneCAN 1 Channel · Communication Wake-Up
150 × 90 × 15 mm Dimensions · Approx. 127 g

Is EF-003 a Fit for Your 8S–14S UAV Battery Pack?

EF-003 CONFIGURATION CHECK

Verify the pack and interface requirements.

Check series count, cell chemistry, current demand, CAN 2.0B integration and board envelope against the EF-003 specification.

8S MINIMUM SERIES REFERENCE 8 cells shown · EF-003 supports 8S–14S
8S–14S 150A Smart BMS for Detection UAV Battery Packs Eight cells are connected in series. Each cell positive terminal connects to the next cell negative terminal. This is a topology reference. + − CELLS 1–4 CELLS 5–8 1 2 3 4 5 6 7 8
Illustrative series-current path Cell positive connects to the next cell negative B− = pack negative · B0–B8 = 8S cell taps · B+ = pack positive

12S1P PACK OPTIONS FOR EF-003

12S UAV battery packs for EF-003 integration

12S1P · 44.4 V LISTED
SMART UAV 25C
12S1P Series
44.4V Voltage
22Ah Capacity
LIPO UAV 25C
12S1P Series
44.4V Voltage
30Ah Capacity
SEMI-SOLID UNLISTED
12S1P Series
44.4V Voltage
26Ah Capacity
SEMI-SOLID UNLISTED
12S1P Series
44.4V Voltage
31Ah Capacity
SEMI-SOLID UNLISTED
12S1P Series
44.4V Voltage
35Ah Capacity
SEMI-SOLID UNLISTED
12S1P Series
44.4V Voltage
45Ah Capacity
PACK INTEGRATION CHECK 12S1P falls within EF-003’s 8S–14S supported series range Confirm cell chemistry, voltage limits and charger settings for each pack The two 25C pack ratings do not set EF-003 discharge current; other C-rates are unlisted Review 80 A charge / 120 A discharge recommendations, terminal rating and CAN mapping
EF-003 · 8S–14S UAV BMS EF-003-8S-14S 150 × 90 × 15 mm · 127 g

EF-003 8S–14S 150A UAV BMS
For NMC and LTO UAV battery packs. Monitors cell voltage, pack current and four NTC inputs, with configurable protection, charge and idle-state balancing, and CAN 2.0B telemetry.

Send Pack Requirements →
Engineering review Pack fit check Configuration guidance

ENGINEERING SPECIFICATIONS

EF-003 Key Specifications

Confirm the 8S–14S cell count, configured protection thresholds and P−/B− terminal rating before setting pack current limits. The 150 A specified maxima are shown separately from the recommended 80 A charge and 120 A discharge limits.

Battery and Electrical
Configuration
Specification
Product Model EF-003
Supported Series-Cell Count 8S–14S
Specified Max. Continuous Charge 150 A
Recommended Max. Continuous Charge 80 A
Specified Max. Continuous Discharge 150 A
Recommended Max. Continuous Discharge 120 A
Peak Discharge Current 200 A / 10 s
Operating Temperature −20°C to 80°C (0°C to 40°C recommended)
P− / B− Terminal Limit 120 A max.
Dimensions 150 × 90 × 15 mm
Weight 127 g
Measurement, Balancing
and Communication
Specification
Cell-Voltage Accuracy ±5 mV at 25°C
Pack-Voltage Accuracy ±0.5% FSR
Current Measurement Accuracy 350 mA at ≤32 A; 1% at >32 A
Temperature Sensing 4 NTC channels
Temperature Measurement Range −20°C to 105°C
Temperature Measurement Accuracy ±1.5°C
Balancing Modes Charge and idle-state balancing
Balancing Activation Software configurable
Historical Data Fault and charge/discharge records via host software
Host-Tool Functions Live data, calibration, CAN ID setup and firmware update
CAN Communication CAN 2.0B, 1 channel; communication wake-up
EF-003 SMART BMS FUNCTIONS

Protection, Communication & Battery Intelligence

Four operating scenarios for security-surveillance and border-patrol UAVs: in-flight temperature warning, anti-spark precharge, multi-protocol communication and high-accuracy SOC estimation.

01 · FLIGHT TEMPERATURE

IN-FLIGHT HIGH-TEMPERATURE WARNING

During flight, a high-temperature discharge condition triggers a warning without interrupting discharge.

Security-surveillance UAV using EF-003 in-flight high-temperature warning
IN-FLIGHT HIGH-TEMPERATURE LOGIC
High Temperature Discharge-temperature condition detected
Warning Only Temperature status is reported
Discharge Enabled No protective discharge cut-off in flight
Designed for security-surveillance and border-patrol UAV flight scenarios where continued power availability is required.
02 · PRECHARGE

PRECHARGE BEFORE MAIN-CIRCUIT CONNECTION

Reduce the voltage difference before the main circuit closes to limit inrush current and connector arcing.

EF-003 precharge process reducing inrush current and connector arcing
PRECHARGE SEQUENCE
BATTERY PACK PRECHARGE MAIN CIRCUIT
The main circuit is connected after the voltage difference is reduced, helping limit surge current and plug arcing during charging connection.
03 · COMMUNICATION

MULTI-PROTOCOL COMMUNICATION

Support data exchange between the BMS, flight-control system and external engineering devices.

EF-003 multi-protocol communication for security-surveillance and border-patrol UAVs
REAL-TIME BMS DATA LINK
EF-003 BMS FLIGHT CONTROL HOST SYSTEM
Multiple communication options support battery-data reporting, flight-control integration and engineering commissioning.
04 · SOC ESTIMATION

HIGH-ACCURACY IN-FLIGHT SOC ESTIMATION

Estimate the remaining battery capacity during flight to support mission and return planning.

EF-003 high-accuracy SOC estimation during UAV flight
REAL-TIME BATTERY-CAPACITY VIEW
≤5% SOC estimation accuracy
In Flight Continuous battery-state estimation
Remaining Power Battery level available to the UAV system

CAN INTERFACE & PACK TELEMETRY

EF-003 CAN Communication & Pack Diagnostics

Read EF-003 pack telemetry and protection flags through the CAN host tool. Match the target flight-controller protocol during system integration.

EF-003 · CAN DATA INTERFACE
CAN 2.0B 1 CAN Channel Communication Wake-Up
Flight Controller CAN message mapping required
EF-003 UAV BMS Pack telemetry · protection flags · MOSFET state
Pack Telemetry
Cell / Pack Voltage Pack Current NTC Temperature SOC Remaining Capacity Fault / MOSFET State
CAN HOST TOOL
Live Telemetry Cell/pack voltage, current, NTC, SOC and MOSFET state
Configuration Protection/recovery thresholds, delays and CAN ID setup
Fault & Data Logs Read fault counts and export operating data
CAN Service Access PC-tool telemetry, calibration and CAN ID setup
Charge/Discharge Logging Records at 1 s intervals; view and export via the PC tool
Firmware Update Update over CAN or UART after verifying BMS communication

Confirm CAN bitrate, message IDs, payload mapping and wake-up commands for the target flight controller before integration.

Configuration Path

Standard EF-003 or an EF-003-Based Custom BMS?

Use standard EF-003 when its 8S–14S range, current limits, CAN 2.0B interface and board envelope fit the pack. Otherwise, request an engineering review of EF-003-based changes.

Standard Platform

Choose Standard EF-003

For UAV packs that fit the EF-003 series-cell range, recommended continuous-current limits and existing hardware interfaces.

  • 8S–14S series-cell configuration
  • 80 A recommended continuous charge / 120 A discharge
  • Four NTC inputs and configurable protection thresholds
  • CAN 2.0B interface and charge/idle-state balancing
Request EF-003 Fit Review →
Engineering Review

Review EF-003 Customization

Assess changes to protection setpoints, current path, wiring, CAN messages or packaging around the EF-003 platform.

  • Chemistry-specific voltage and temperature setpoints
  • Current-path, connector and harness requirements
  • Flight-controller CAN message mapping
  • Board envelope or firmware behavior changes
Explore EF-003 Customization →
Before selecting a path: confirm cell chemistry, series count, continuous and peak-current duty cycle, CAN protocol, connector plan and available mounting envelope.

EF-003 Engineering & Procurement FAQ

Which battery packs can EF-003 support?+

EF-003 is a smart UAV BMS for battery packs with 8–14 series-connected cells (8S–14S). Confirm the supported cell chemistry, pack capacity and maximum charge voltage for the supplied configuration. Protection and balancing settings must match the selected cells and charger; voltage limits for one cell chemistry should not be applied to every 8S–14S pack.

How should EF-003 be sized for continuous and peak current?+

The datasheet lists 150 A maximum continuous charge/discharge and 200 A peak discharge for 10 s. Recommended operating conditions are up to 80 A continuous charge, 120 A continuous discharge and 0–40°C. The same document lists 120 A B−/P− terminals and a configurable 100 A default charge-overcurrent threshold. Confirm the terminal rating, thermal conditions and protection settings with Ayaa before specifying a 150 A continuous duty cycle.

What is the correct EF-003 wiring and first power-on sequence?+

Follow the confirmed EF-003 wiring diagram for your series-cell configuration. Connect B− first, then B+ and P+, followed by the cell-sense connectors from lowest to highest cell potential. Complete all wiring before connecting a charger or load. Activate the BMS by charging or using the pushbutton. For removal, disconnect the charger and load first, then the cell-sense connectors from highest to lowest potential, followed by B+ and B−.

Can EF-003 provide battery telemetry to an ArduPilot or PX4 flight controller?+

EF-003 provides one CAN 2.0B channel with communication wake-up. Native DroneCAN compatibility is not established by the current datasheet. Confirm the CAN bitrate, identifier format, message IDs, payload scaling and battery-message mapping against your flight-controller firmware. The PC tool displays cell and pack voltage, current, temperature, SOC, remaining capacity and protection status; confirm which fields the supplied CAN protocol makes available to the flight controller.

Can EF-003 protection thresholds and cell balancing be configured?+

Yes. The PC tool supports voltage, temperature and charge/discharge overcurrent protection settings, together with the applicable recovery thresholds and delays. EF-003 supports balancing during charging and at rest, with software-configurable activation conditions. Confirm the balancing current and exact start/stop criteria for the supplied configuration. Set protection and balancing parameters from the cell datasheet and pack operating requirements.

What should buyers confirm before placing an EF-003 order?+

Provide the cell datasheet, series count, capacity, charge/discharge duty cycle, flight-controller protocol, harness requirements and order quantity. Request the latest confirmed specification, hardware/firmware revision, wiring diagram, CAN protocol, included accessories, MOQ, sample availability, quotation, lead time and applicable certification documents. The datasheet states a 12-month warranty under normal use. Exclusions include improper use, operation outside specified conditions, unauthorized disassembly or repair, and water or moisture damage.

EF-003 vs EF-009: Compare 8S–12S UAV Battery Requirements

8S–12S is the shared NMC pack range. Both models carry a 150 A headline, but their published charge and discharge guidance differs. Compare the duty cycle, communication, pack architecture and mounting space before selection.

Selection Factor EF-003 8S–14S 150A UAV battery management system EF-003 8S–14S UAV Battery Management System EF-009 6S–12S 150A NMC UAV battery management system EF-009 6S–12S NMC UAV Battery Management System
Battery Chemistry and Project Fit NMC UAV packs on the current product page; the EF-003 specification also lists LiFePO4 and LTO, subject to pack-specific configuration review 6S–12S NMC Li-ion UAV packs using the published common-port configuration
Supported Battery Configuration 8S–14S 6S–12S
Nominal NMC Pack Voltage 29.6–51.8 V (8S–14S at 3.7 V/cell) 22.2–44.4 V (6S–12S at 3.7 V/cell)
Board Dimensions 150 × 90 × 15 mm 125 × 63 × 14.5 mm
Continuous Charge / Discharge Current Recommended: up to 80 A charge / 120 A discharge. Specified maxima: 150 A each; P−/B− terminals are rated 120 A max. 30 A charge / 150 A continuous discharge (1-hour rating stated on the product page)
Series-Count Selection 8S–12S overlaps with EF-009; EF-003 also covers 13S–14S 8S–12S overlaps with EF-003; EF-009 also covers 6S–7S
Balancing and Pack Architecture Charge and rest balancing; 2–4 packs in parallel discharge with unique battery IDs 42 ± 10 mA passive balancing during charging; common-port architecture
Communication and Integration CAN 2.0B with communication wake-up; Type-C host-tool access. Confirm flight-controller protocol requirements for the project. CAN 2.0 for equipment data; UART / RS485 host-tool access. The EF-009 product page states no flight-control protocol support.
Choose This Model When You need 13S–14S, parallel-pack discharge, or an 8S–12S design needing more than 30 A charge current within EF-003's recommended limits You need 6S–7S, or an 8S–12S NMC design with up to 150 A continuous discharge, charging at no more than 30 A, and no flight-control protocol requirement
Request EF-003 Review → View EF-009 Details →

EF-003 UAV BMS INTEGRATION

Review Your
EF-003 Integration

Share your 8S–14S battery configuration, charge/discharge duty cycle and flight-controller interface. Request a review of EF-003 current limits, protection settings and CAN protocol requirements for your UAV battery pack.

8S–14S Series-cell configuration
80 A / 120 A Recommended continuous charge / discharge
DroneCAN 1 channel · CAN protocol review
EF-003 INTEGRATION REQUEST

Request an EF-003 Integration Review

8S–14S · UAV BMS · CAN 2.0B
✓ Battery-pack and CAN interface review ✓ Information used for technical follow-up