Leave Your Message

AYAA · SMART POWER FOR UAVs

EF-006 12S 81A Smart UAV BMS

EF-006 is a smart BMS for 12S UAV lithium battery packs, supporting 81A continuous discharge and 27A charging through one port. It monitors cell voltage, current, and temperature, and provides passive balancing, isolated CAN, Bluetooth, and battery history. In flight, voltage, current, and temperature anomalies are reported as alerts rather than triggering protection.

12S Battery Configuration
27A Continuous Charge Current
81A Continuous Discharge Current
DroneCAN + BLE Communication Interfaces
123.8 × 94.8 × 11 mm Board Dimensions (±1 mm)

Is EF-006 Right for Your 12S UAV Battery Pack?

12S CONFIGURATION CHECK

Match the pack before integration.

Compare your 12S pack chemistry, charge-voltage limit, current demand, CAN requirements and installation space with the EF-006 specification.

12S SERIES REFERENCE 12 cells total · 6 cells per row
12S 81A Smart BMS for Inspection UAV Battery Packs Twelve lithium battery cells appear in two rows of six, numbered 1–6 left to right and 7–12 right to left. Each positive terminal connects to the next cell's negative terminal in one 12-cell series chain. + − CELLS 1–6 CELLS 7–12 1 2 3 4 5 6 7 8 9 10 11 12
Animated series-current path Cell positive connects to the next cell negative B− = pack negative · 1–12 = voltage-sensing points · B+ = pack positive

12S1P · 44.4V NOMINAL

12S1P battery pack options for EF-006

EF-006 · 81A DISCHARGE
Smart UAV Battery 25C
12S1P Series
44.4V Voltage
22 Cap. (Ah)
LiPo UAV Battery 25C
12S1P Series
44.4V Voltage
30 Cap. (Ah)
Semi-Solid UAV
12S1P Series
44.4V Voltage
26/31 Cap. (Ah)
Semi-Solid UAV
12S1P Series
44.4V Voltage
35/45 Cap. (Ah)
High-Voltage Semi-Solid
12S1P Series
44.4V Voltage
24.5/41 Cap. (Ah)
High-Voltage Semi-Solid
12S1P Series
44.4V Voltage
55/67 Cap. (Ah)
EF-006 FIT CHECK Listed packs: 12S1P, 44.4V nominal EF-006: 27A continuous charge, 81A continuous discharge Confirm 50.4V charge limit for high-voltage semi-solid packs Verify peak current, connectors, CAN protocol and installation space
12S · 81A BMS EF-006 12S 81A smart UAV BMS product 123.8 × 94.8 × 11 mm

EF-006 12S 81A Smart UAV BMS
Monitors cell voltage, current and temperature in 12S UAV packs. It supports 27A continuous charging, passive balancing, isolated CAN, Bluetooth and battery history. During flight, anomalies are reported as alerts rather than protective shutdown.

12S · 44.4V nominal 27A Charge · 81A Discharge Isolated CAN + BLE 50mA Typical Balance
Share Project Requirements →
◉ Engineering review ♧ Project-fit check ϟ Configuration guidance

ENGINEERING SPECIFICATIONS

EF-006 Key Specifications

EF-006 is a 12S smart UAV BMS with a common charge/discharge port. Review the 50.4 V charging voltage, continuous-current limits, balancing, communication and installation dimensions before pack integration.

Battery and Electrical
Configuration
Specification
Product Model EF-006
Battery Pack Configuration 12S
Charging Voltage 50.4 V
Continuous Charging Current 27 A
Continuous Discharging Current 81 A
Port Configuration Common charge/discharge port
Output Mode MOSFET
Operating Temperature −20°C to 70°C
Dimensions 123.8 × 94.8 × 11 mm (±1 mm)
PCBA Coating Conformal coating
Voltage/Current/Temperature Response Ground protection; in-flight alerts only
Monitoring, Balancing
and Communication
Specification
NTC Temperature Sensors 3 battery channels + 1 MOS channel
Balancing Method Passive
Balancing Current 50 mA typical (40–60 mA)
Balancing Start Voltage 3.8 V typical
Balancing Start Difference 50 mV typical
CAN Communication Isolated; 1 Mbps; default BMS ID 1
CAN Termination 120 Ω resistor included
BLE Communication Standard; 115200 baud; ID 1
Operating Consumption ≤10 mA
Sleep Consumption ≤3 mA (BLE operating)
Deep-Sleep Consumption ≤50 µA (cell undervoltage)
EF-006 SMART BMS FUNCTIONS

Protection, Communication & Battery Intelligence

Four operating scenarios for security-surveillance and border-patrol UAVs: in-flight temperature warning, anti-spark precharge, multi-protocol communication and high-accuracy SOC estimation.

01 · FLIGHT TEMPERATURE

IN-FLIGHT HIGH-TEMPERATURE WARNING

During flight, a high-temperature discharge condition triggers a warning without interrupting discharge.

Security-surveillance UAV using EF-006 in-flight high-temperature warning
IN-FLIGHT HIGH-TEMPERATURE LOGIC
High Temperature Discharge-temperature condition detected
Warning Only Temperature status is reported
Discharge Enabled No protective discharge cut-off in flight
Designed for security-surveillance and border-patrol UAV flight scenarios where continued power availability is required.
02 · PRECHARGE

PRECHARGE BEFORE MAIN-CIRCUIT CONNECTION

Reduce the voltage difference before the main circuit closes to limit inrush current and connector arcing.

EF-006 precharge process reducing inrush current and connector arcing
PRECHARGE SEQUENCE
BATTERY PACK PRECHARGE MAIN CIRCUIT
The main circuit is connected after the voltage difference is reduced, helping limit surge current and plug arcing during charging connection.
03 · COMMUNICATION

MULTI-PROTOCOL COMMUNICATION

Support data exchange between the BMS, flight-control system and external engineering devices.

EF-006 multi-protocol communication for security-surveillance and border-patrol UAVs
REAL-TIME BMS DATA LINK
EF-006 BMS FLIGHT CONTROL HOST SYSTEM
Multiple communication options support battery-data reporting, flight-control integration and engineering commissioning.
04 · SOC ESTIMATION

HIGH-ACCURACY IN-FLIGHT SOC ESTIMATION

Estimate the remaining battery capacity during flight to support mission and return planning.

EF-006 high-accuracy SOC estimation during UAV flight
REAL-TIME BATTERY-CAPACITY VIEW
≤5% SOC estimation accuracy
In Flight Continuous battery-state estimation
Remaining Power Battery level available to the UAV system

CONNECTED BATTERY DATA

CAN Communication, Host Software & Battery Data

Connect EF-006 through isolated CAN and view battery status through host software or BLE.

EF-006 · DATA CONNECTION
Isolated CAN 1 Mbps BMS ID 1
Flight Controller Confirm CAN protocol compatibility
EF-006 Smart BMS 12S monitoring · status · history
Battery Data
Cell / pack voltage Current Temperature SOC Remaining capacity Protection status
HOST SOFTWARE
Live View Cell, pack and protection data
Settings Threshold · recovery · delay
History Fault records and data export
CAN + BLE Access Host and wireless battery-data access
Historical Battery Data View fault records and export operating data
Engineering Commissioning Authorized settings and firmware updates

Confirm the flight-controller protocol and CAN configuration before integration.

Product Demonstration

EF-006 Bench Demonstration: Host Software & CAN

See the EF-006 bench setup, host-software battery display and CAN tool interface. Use the engineering checklist to review your own 12S pack integration.

Configuration Path

Standard EF-006 or Custom UAV BMS?

Choose EF-006 for a matching 12S UAV battery project, or share requirements outside its standard configuration for an engineering review.

Standard Platform

Choose Standard EF-006

A 12S smart BMS platform for UAV battery projects that match its electrical, communication and installation requirements.

  • 12S battery-pack configuration
  • 27A continuous charge and 81A continuous discharge
  • Isolated CAN and BLE communication
  • Cell monitoring, passive balancing and history storage
Request Compatibility Review →
Engineering Review

Discuss a Custom BMS

For battery packs, interfaces or control requirements outside the standard EF-006 configuration.

  • Different cell count or battery chemistry
  • Project-specific current or wiring requirements
  • Custom communication or protocol requirements
  • Project-specific hardware or software settings
Discuss Custom Requirements →
Before integration: please confirm battery chemistry, series count, current requirement, flight-controller protocol and installation space.

EF-006 12S Battery Pack Engineering FAQ

Are all listed 12S1P battery packs ready to use with EF-006?+

The listed 44.4 V nominal packs include smart and LiPo, semi-solid, and high-voltage semi-solid options. Matching 12S1P does not establish electrical compatibility by itself. Confirm each pack's chemistry, maximum charging voltage, continuous and peak current, connector layout, and installation space before integration. High-voltage semi-solid packs need a specific charging-voltage review.

Does a 25C rating or higher pack capacity increase the EF-006 current limit?+

No. The pack's C rating and capacity describe the battery, while this EF-006 configuration is specified for 27 A continuous charging and 81 A continuous discharging. Compare the UAV's actual continuous load, peak-current duration, charger output, cables, and connectors with those limits. Ask for an engineering review if the project needs more current.

How should the 12S voltage-sensing and power connections be checked?+

In the EF-006 pin definitions, GND and B0 connect to cell 1 negative; B1 through B12 connect to the positive side of their corresponding cells. The charge and discharge paths share a port with P+ and P− terminals. Check cell order, polarity, connector pinout, and the complete wiring diagram in the EF-006 specification before applying power.

What must match for the flight controller to read EF-006 CAN data?+

EF-006 provides isolated CAN at 1 Mbps with default BMS ID 1, and its CAN interface includes a 120 Ω termination resistor. Confirm the flight controller's message protocol, signal mapping, bus wiring, and termination arrangement during integration. A matching CAN connector and baud rate alone do not confirm protocol compatibility.

When does EF-006 passive balancing start?+

The typical balancing start voltage is 3.8 V per cell, with a typical 50 mV cell-voltage difference condition. Typical passive balancing current is 50 mA. Check initial cell matching and pack behavior separately; the balancing function is not a substitute for confirming that the cells and pack design are suitable.

Will EF-006 disconnect the battery when an anomaly occurs during flight?+

The EF-006 specification describes protection against voltage, current, and temperature anomalies during ground operation. During flight, those anomalies are reported through alarms and communication data without triggering protective shutdown. The flight controller and operating procedure should account for those alerts.

EF-006 vs EF-007 vs EF-013: Compare 12S UAV BMS Options

All three models support 12S battery packs. Compare continuous charge and discharge current, heating, balancing and interfaces, then confirm your pack chemistry, wiring and flight-controller protocol.

Selection Factor EF-006 12S 81A Smart UAV BMS EF-006 12S 81A Smart UAV BMS EF-007 12S 120A Smart UAV BMS EF-007 12S 120A Smart UAV BMS EF-013 12S 150A Smart UAV BMS EF-013 12S 150A Smart UAV BMS
Best-Fit UAV Application 12S inspection and detection UAVs within the 81 A continuous discharge rating 12S inspection or mapping UAVs needing 120 A continuous current or battery heating 12S inspection or surveillance UAVs needing 150 A continuous discharge
Supported Battery Configuration 12S 12S 12S
Nominal Pack Voltage 44.4 V 44.4 V 44.4 V
Continuous Charging Current 27 A 120 A for the configuration shown on its product page 20 A
Continuous Discharging Current 81 A 120 A for the configuration shown on its product page 150 A
Key Platform Capability 50 mA typical passive balancing with cell monitoring and battery history access Charge-powered battery heating with multi-point temperature monitoring and history storage 70 mA typical passive balancing with three cell, one MOS and one connector temperature channels
Communication and Integration Isolated CAN at 1 Mbps (default BMS ID 1) and Bluetooth data access CAN, RS485 and UART interface options; confirm the selected Bluetooth and flight-controller protocol configuration CAN at 1 Mbps (default BMS ID 1) and standard BLE; no RS485 or UART
Choose This Model When Your pack is 12S and your system stays within 27 A continuous charging and 81 A continuous discharging Your 12S pack needs the shown 120 A current configuration or charge-powered heating Your 12S pack needs up to 150 A continuous discharge and no more than 20 A continuous charge
Request EF-006 Review → View EF-007 Details → View EF-013 Details →

EF-006 UAV BMS INTEGRATION

Confirm Your
EF-006 Integration

Tell us about your 12S UAV battery pack, charger and flight controller. Our engineers can review EF-006 fit against its 50.4 V charging voltage, 27 A continuous charge, 81 A continuous discharge and communication requirements.

12S UAV lithium battery pack
81 A Continuous discharge current
27 A Continuous charge current
EF-006 INTEGRATION REQUEST

Request an EF-006 Compatibility Review

12S · 27 A Charge · 81 A Discharge
✓ Product compatibility review ✓ Information used for technical follow-up